Description
On sale FLUKE 117F Electricans Digital Multimeter With Non-Contact Voltage ELECTRICANS DIGITAL MULTIMETER.
Fluke 117 Electrician’s Multimeter with Non-Contact voltage
Designed by electricians. Engineered by Fluke.
Compact true-rms meter for commercial applications. TheFluke 117 is the ideal meter for demanding settings like commercial buildings, hospitals and schools. The 117 includes integrated non-contact voltage detection to help get the job done faster.
- VoltAlert™ technology for non-contact voltage detection
- AutoVolt automatic ac/dc voltage selection
- Low input impedance: helps prevent false readings due to ghost voltage
- Large white LED backlight to work in poorly lit areas
- True-rms for accurate measurements on non-linear loads
- Measures 10 A (20 A overload for 30-seconds)
- Resistance, continuity, frequency and capacitance
- Min/Max/Average with elapsed time to record signal fluctuations
- Compact ergonomic design for one-handed operation
- Compatible with optional magnetic hanger (ToolPak™) for hands free operation
- CAT III 600 V safety rated
Specifications |
Maximum voltage between any terminaland earth ground | |
Surge protection | | 6 kV peak per IEC 61010-1 600 V CAT III,Pollution Degree 2 |
|
Fuse for A input | | 11 A, 1000 V FAST Fuse (Fluke PN 803293) |
|
Display | Digital: | 6,000 counts, updates 4 per second |
|
Bar graph | | 33 segments, updates 32 per second |
|
Operating Temperature | |
Storage Temperature | |
Battery type | | 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
|
Battery Life | | 400 hours typical, without backlight |
|
_
Accuracy Specifications |
DC millivolts | Range: | 600.0 mV | Resolution: | 0.1 mV | Accuracy: | ± ([% of reading] + [counts]): 0.5% + 2 |
|
DC volts | Range/Resolution: | 6.000 V / 0.001 V | Range/Resolution: | 60.00 V / 0.01 V | Range/Resolution: | 600.00 V / 0.1 V | Accuracy: | ± ([% of reading] + [counts]): 0.5% + 2 |
|
Auto volts | Range: | 600.0 V | Resolution: | 0.1 V | Accuracy: | 2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz) |
|
AC millivolts1 true-rms | Range: | 600.0 mV | Resolution: | 0.1 mV | Accuracy: | 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) |
|
AC volts1 true-rms | Range/Resolution: | 6.000 V / 0.001 V | Range/Resolution: | 60.00 V / 0.01 V | Range/Resolution: | 600.0 V / 0.1 V | Accuracy: | 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) |
|
Continuity | Range: | 600 Ω | Resolution: | 1 Ω | Accuracy: | Beeper on 250 Ω; detects opens or shorts of 500 μs or longer. |
|
Ohms | Range/Resolution: | 600.0 Ω / 0.1 Ω | Range/Resolution: | 6.000 kΩ / 0.001 kΩ | Range/Resolution: | 60.00 kΩ / 0.01 kΩ | Range/Resolution: | 600.0 kΩ / 0.1 kΩ | Range/Resolution: | 6.000 MΩ / 0.001 MΩ | Accuracy: | 0.9 % + 1 | Range/Resolution: | 40.00 MΩ / 0.01 MΩ | Accuracy: | 1.5 % + 2 |
|
Diode Test | Range/Resolution: | 2.000 V / 0.001 V | Accuracy: | 0.9% + 2 |
|
Capacitance | Range/Resolution: | 1000 nF / 1 nF | Range/Resolution: | 10.00 μF / 0.01 μF | Range/Resolution: | 100.0 μF / 0.1 μF | Range/Resolution: | 9999 μF / 1 μF | Range/Resolution: | 100 μF to 1000 μF | Accuracy: | 1.9% + 2 | Range/Resolution: | > 1000 μF | Accuracy: | 5% + 20% |
|
LoZ capacitance | Range: | 1 nF to 500 μF | Accuracy: | 10% + 2 typical |
|
AC amps true-rms (45 Hz to 500 Hz) | Range/Resolution: | 6.000 A / 0.001 A | Range/Resolution: | 10.00 A / 0.01 A | Accuracy: | 1.5% + 3 | | 20 A continuous overload for 30 seconds max |
|
DC amps | Range/Resolution: | 6.000 A / 0.001 A | Range/Resolution: | 10.00 A / 0.01 A | Accuracy: | 1.0% + 3 | | 20 A continuous overload for 30 seconds max |
|
Hz (V or A input)2 | Range/Resolution: | 99.99 Hz / 0.01 Hz | Range/Resolution: | 999.99 Hz / 0.1 Hz | Range/Resolution: | 9.999 Hz / 0.001 Hz | Range/Resolution: | 50.00 Hz / 0.01 Hz | Accuracy: | 0.1% + 2 |
|
Notes:
1) All ac voltage ranges exept Auto – V / Lo-Z are specified from 1% to 100% of range. Auto – V / Lo-Z is specified from 0.0V.
2) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage.
Weight: 0.739
Aussie Stock
All our stock is kept in our Melbourne based warehouse. Our stock levels are also updated every 10 minutes! So if it says 10 units in stock, you can trust that it is accurate.
No PO Boxes or Parcel Lockers
At this stage we only use couriers and can only deliver to a road-side address. This means PO Boxes and Parcel Lockers cannot be accepted as StarTrack do not deliver to these addresses.
In instances where a PO Box or Parcel Locker address in entered, we may ask for an alternative road-side address, or cancel and refund your order immediately and urge you to replace your order with an alternative delivery address.
Delivery times
We typically dispatch our goods same day or next day. From there, you can expect 2 – 8 business days Australia wide. Most capital cities can expect 1-2 day delivery times.
Any RTS (Return to Sender) orders due to missing or incorrect address information entered by the buyer may incur an additional charge for redelivery.
. Browse our range of Fluke products available on sale in Australia.
Only logged in customers who have purchased this product may leave a review.
Reviews
There are no reviews yet.